首页 | 本学科首页   官方微博 | 高级检索  
     

应用傅立叶变换近红外光谱检测婴幼儿配方奶粉中的乳糖含量
引用本文:何吉子,陈秀明,梁瑞婷,李双,张仕云,麦丽珊.应用傅立叶变换近红外光谱检测婴幼儿配方奶粉中的乳糖含量[J].中国酿造,2019,38(3):193.
作者姓名:何吉子  陈秀明  梁瑞婷  李双  张仕云  麦丽珊
作者单位:1.广东检验检疫技术中心,广东 广州 510623;2.南沙海关,广东 广州 510623; 3.广东省动植物与食品进出口技术措施研究重点实验室,广东 广州 510623;4.北京师范大学 香港浸会大学联合国际学院 珠海市农产品质量与食品安全重点实验室,广东 珠海 519000
基金项目:珠海市高等教育建设项目-珠海市农产品质量与食品安全重点实验室开发基金(ZKLF-201602);国家质量监督检验检疫总局科技计划项目(2017IK68);广东检验检疫局科技计划项目(2017GDK45)
摘    要:利用傅立叶变换近红外光谱(FT-NIR)技术结合偏最小二乘法(PLS)对婴幼儿配方奶粉中的乳糖进行快速检测分析。搜集 94个不同产地、不同品牌的婴幼儿配方奶粉中乳糖的实验室数据,并采集婴幼儿配方奶粉的近红外光谱图,选择最优的光谱预处理方法,优化、验证和建立模型,并预测6个未知品牌的婴幼儿配方奶粉样品的乳糖含量。结果表明,不同阶段的婴幼儿配方奶粉有非常相似 的近红外特征图谱,图谱处理后的方差为95.423 5%,该模型测定的乳糖值与高效液相色谱(HPLC)法测定的乳糖值之间的平均相对误 差均≤0.67%,相对标准偏差(RSD)均≤0.88%,均符合误差范围。该方法可以无损、快速、高效地测定婴幼儿配方奶粉中的乳糖含量。

关 键 词:傅立叶变换近红外光谱  婴幼儿配方奶粉  乳糖含量  检测  

Determination of lactose content in infant formula milk powder based on Fourier transform near-infrared spectroscopy
HE Jizi,CHEN Xiuming,LIANG Ruiting,LI Shuang,ZHANG Shiyun,MAI Lishan.Determination of lactose content in infant formula milk powder based on Fourier transform near-infrared spectroscopy[J].China Brewing,2019,38(3):193.
Authors:HE Jizi  CHEN Xiuming  LIANG Ruiting  LI Shuang  ZHANG Shiyun  MAI Lishan
Affiliation:1.Guangdong Inspection and Quarantine Technology Center, Guangzhou 510623, China; 2.Nansha Customs, Guangzhou 510623, China; 3.Guangdong Key Laboratory of Import and Export Technical Measures of Animal, Plant and Food, Guangzhou 510623, China; 4. Zhuhai Key Laboratory of Agricultural Product Quality and Food Safety, BNU-HKBU United International College, Beijing Normal University, Zhuhai 519000, China
Abstract:Th e lactose content in infant formula milk powder was rapidly detected and analyzed by Fourier transform near-infrared spectroscopy (FT-NIR) combined with partial least squares (PLS). 94 samples of infant formula milk powder from different originals and brands were collected, and NIR spectra of all infant formula milk powder were collected. The optimal pre-treatment method of spectra was chosen, and then the model was optimized, verified, and established, and the lactate content of 6 samples of unknown infant formula milk powder were forecasted. The results showed that different infant formula milk powder had the same NIR spectrum, the variance of the spectra after treatment was 95.423 5%, the average relative errors of lactose values determined by the model and HPLC method were less than 0.67%, the relative standard deviation (RSD) was less than 0.88%, and all of them were conformed to the error range. The results showed that method could determine lactate content in infant formula milk powder nondestructively, rapidly and efficiently.
Keywords:Fourier transform near-infrared spectroscopy  infant formula milk powder  lactose content  determination  
本文献已被 CNKI 等数据库收录!
点击此处可从《中国酿造》浏览原始摘要信息
点击此处可从《中国酿造》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号