首页 | 本学科首页   官方微博 | 高级检索  
     


SCALE calculation for evaluation of spent fuel condition during long-term storage
Authors:M  V  
Affiliation:aDepartment of Nuclear Physics and Technology, Slovak University of Technology Bratislava, Ilkovičova 3, 812 19 Bratislava, Slovakia
Abstract:Experiences with an advanced spent nuclear fuel management in Slovakia are presented in this paper. The evaluation and monitoring procedures are based on practices at the Slovak wet interim spent fuel storage facility in NPP Jaslovské Bohunice. Since 1999, leak testing of WWER-440 fuel assemblies were completed using a special leak tightness detection system developed by Framatome-anp, “Sipping in Pool”. This system utilized external heating for the precise defects determination.Optimal methods for spent fuel disposal and monitoring were designed. A new conservative factor for specifying of spent fuel leak tightness is introduced in the paper. Limit values of leak tightness were established from the combination of SCALE4.4a (ORIGEN-ARP) calculations and measurements from the “Sipping in Pool” system. These limit values are: limiting fuel cladding leak tightness coefficient for tight fuel assembly – kFCT(T) = 3 × 10−10, limiting fuel cladding leak tightness coefficient for fuel assembly with leakage – kFCT(L) = 8 × 10−7.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号