首页 | 本学科首页   官方微博 | 高级检索  
     

600MW机组锅炉高温受热面炉内壁温测量初探
引用本文:张爱军,王鹏,朱宪然,任金磊,李研辉.600MW机组锅炉高温受热面炉内壁温测量初探[J].华北电力技术,2011(6):27-30.
作者姓名:张爱军  王鹏  朱宪然  任金磊  李研辉
作者单位:1. 内蒙古大唐国际托克托发电有限责任公司,内蒙古托克托,010206
2. 华北电力科学研究院有限责任公司,北京,100045
摘    要:测量了一台600 MW自然循环亚临界参数锅炉部分屏式过热器、高温过热器和高温再热器管段的炉内管壁温度,测量一次元件选用镍铬一镍硅铠装热电偶,并对热电偶与管壁的接触点处进行了保温处理,介绍了测点的布置工艺.在锅炉低、中、高等不同稳定负荷下对上述管壁温度进行了测量,结果证明在锅炉中低负荷下,实测温度可以与表盘显示温度保持较...

关 键 词:壁温  受热面  热电偶

Primary Attempt of Wall Temperature Measurement for High Temperature Surfaces in 600 MW Subcritical Boiler
Zhang Ai-jun,Wang Peng,Zhu Xian-ran,Ren Jin-lei,Li Yan-hui.Primary Attempt of Wall Temperature Measurement for High Temperature Surfaces in 600 MW Subcritical Boiler[J].North China Electric Power,2011(6):27-30.
Authors:Zhang Ai-jun  Wang Peng  Zhu Xian-ran  Ren Jin-lei  Li Yan-hui
Affiliation:1.Inner Mongolia Datang International Tuoketuo Power Generation Co.Ltd.,Tuoketuo 010206,China;2.North China Electric Power Research Institute Co.Ltd.,Beijing 100045,China)
Abstract:The wall temperatures of the platen superheater,high temperature superheater and high temperature reheater were measured for a subcritical boiler of 600 MW unit.The armored nickel chromium-nickel silicon thermocouple was adopted as the primary element for measuring,and the joints of the thermocouples and the heating surfaces were heat insulated.The different running conditions of the boiler were prepared for the measuring of walls temperatures.The result showed that the measured values of the wall temperatures could match well those of the DCS panel when the boiler load was low,while the measurement would be invalid when the boiler load was high.The possible reasons were the choice of the improper thermocouple and the deficient heat insulation.Further study and analysis should be made for more precise measurement of the wall temperatures in the boiler.
Keywords:wall temperature  heating surface  thermocouple