摘    要:某220 kV变电站66 kV系统中性点未带消弧线圈对母线加压,产生谐振,导致TV绝缘破损,次日凌晨发生TV爆炸,该母线全停电,通过对故障录波图的分析,还原了谐振发生的暂态过程,深入分析谐振发生的原因。

关 键 词:送电操作  故障录波图  谐振  电压互感器

The Analysis and Discussion of Fault Oscillograph in a Resonance Accident
WANG Rui,WANG Bao-chang,YANG Guang-zhong,XU Fu-bin.The Analysis and Discussion of Fault Oscillograph in a Resonance Accident[J].Northeast Electric Power Technology,2014(5):35-38.
Authors:WANG Rui  WANG Bao-chang  YANG Guang-zhong  XU Fu-bin
Affiliation:(State Grid Dalian Power Supply Company, Dalian, Liaoning 116000 China)
Abstract:In the 66 kV system of a 220 kV substation, the neutral point without arc suppression coil puts pressure on bus bar, which produces resonance. Then the TV insulation got damaged, and the TV explosion caused the bus power outage in next early morning. In this paper, through the analysis of the fault oscillograph, the transient process is restore in detail, and how the resonance occurred and causes of the resonance is analyzed.
Keywords:power operation  fault oscillograph  resonance  voltage transformer