Dynamic evaluation of maximum power point tracking operation with PV array simulator
Authors:Hiroshi Matsukawa  Koukichi Koshiishi  Hirotaka Koizumi  Kosuke Kurokawa  Masayasu Hamada  Liu Bo
Affiliation:a Resources Total System Co. Ltd., 5 Floor Kyoritsu Building, 2-3-11 Shinkawa Chuo-ku, Tokyo 140-0033, Japan;b Tokyo University of Agriculture and Technology, 2-24-16 Naka-cho, Koganei, Tokyo 184-8588, Japan;c Myway Labs Co., Ltd., 1-19-3 Shinyokohama, Kohoku-ku, Yokohama, Kanagawa 222-0033, Japan
Abstract:This paper presents an innovative method to measure the dynamic control ability of maximum power point tracking for PV inverters under the condition of irradiance fluctuation. The PV array I–V curve simulator is a kind of indoor testing facility and easy to be adopted by industries. Basic functions are given by a specially designed PV array I–V curve simulator composed of the active power load. Most of the parameters are controllable by sophisticated software with capability of treating a lot of 1-s data for a very long period of time. In this paper, detailed structure of the equipment is described and test examples are also given by using a commercial PV inverter.
Keywords:Photovoltaic system  Inverter  MPPT  Array simulator  I–  V curve  Irradiance
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号