A Calibration Method Based on Linear InGaAs in Fiber Grating Sensors Interrogation System
Authors:TAO Jun  ZHANG Xia
Affiliation:1.Physics School of Science;Wuhan University of Technology;Wuhan 430070;CHN;2.Digital Engineering Research Center;Huazhong University of Science and Technology;Wuhan 430074;CHN
Abstract:In accordance with the characteristics of wavelength shift detection in fiber grating sensor interrogation system, the wavelength interrogation system which uses linear InGaAs as the spectrum receiver is proposed. Orientation of optic spectrum line affects the silt of volume phase grating and size of InGaAs photosensitive unit, thus the calibration method is needed. Based on an analysis of InGaAs imaging model, least square curve fitting method is proposed to detect spectrum wavelength and InGaAs photosensitive unit position. The experimental results show that the methods are effective and the demodulation system precision is improved.
Keywords:fiber grating sensor interrogation  linear InGaAs  spectrum wavelength  least square curve fitting