Development of high voltage power supply for the KSTAR 170 GHz ECH and CD system |
| |
Authors: | J.H. Jeong Y.S. Bae M. Joung H.J. Kim S.I. Park W.S. Han J.S. Kim H.L. Yang J.G. Kwak K. Sakamoto K. Kajiwara Y. Oda K. Hayashi |
| |
Affiliation: | 1. National Fusion Research Institute, Daejeon, Republic of Korea;2. Japan Atomic Energy Agency, Naka, Japan |
| |
Abstract: | A 3.6 MW (66 kV/55 A) DC power supply system was developed for the 170 GHz EC H&CD system in KSTAR. The power supply system consists of a cathode power supply (CPS), an anode power supply (APS) and a body power supply (BPS). The cathode power supply is capable of supplying a maximum voltage of ?66 kV and a current of 55 A to the cathode with respect to the collector using pulse step modulation (PSM). The high voltage switching system for the cathode is made by a fast MOS-FET solid-state switch which can turn off the high voltage to the cathode within 3 μs in the occurrence of gyrotron faults. The APS is a voltage divider system consisting of a fixed resistor and zener diode units with the capability of 60 kV stand-off voltage. The anode voltage with respect to the cathode is controlled in a range of 0–60 kV by turning the MOS-FET switches connected in parallel to each zener diode on and off. For high frequency current modulation of the gyrotron, the parallel discharge switch is introduced between the cathode and anode in order to clamp the charged voltage in the stray capacitance. The BPS is a DC power supply with the capability of 50 kV/160 mA. The nominal operation parameter of BPS was 23 kV and 10 mA, respectively, and the voltage output is regulated with a stability of 0.025% of the rated voltage. The series MOS-FET solid-state switch is used for on/off modulation in the body voltage sychronizing with anode voltage. The parallel discharge switch is also introduced between the body and collector for high frequency RF modulation. This paper describes the key features of the high voltage power supply system of the KSTAR 170 GHz gyrotron as well as the test results of the power supply. |
| |
Keywords: | ECH ECCD High voltage power supply Gyrotron |
本文献已被 ScienceDirect 等数据库收录! |