首页 | 本学科首页   官方微博 | 高级检索  
     


KATHELO: A new high heat flux component testing facility
Authors:B.E. Ghidersa  X. Jin  M. Rieth  M. Ionescu-Bujor
Affiliation:Karlsruhe Institute of Technology (KIT), Germany
Abstract:In this article a new helium cooled test facility is presented. The loop, KATHELO, is designed to operate at pressures up to 10 MPa and temperatures up to 800 °C in order to be able to provide suitable testing conditions for the helium cooled divertor concept developed at KIT. The general layout of the loop is introduced and the some of the technological solutions adopted for the loop components are discussed. The thermal-dynamic behavior of the loop during start-up and steady state operation for two different scenarios is analyzed using a RELAP-3D model of the circuit. Based on these simulations the heating power needed for high temperature operation is estimated. A particular attention is given to the thermal coupling between the cold and hot leg of the loop with emphasis on overall loop efficiency.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号