首页 | 本学科首页   官方微博 | 高级检索  
     


Real-time AC voltage control and power-following of a combined proton exchange membrane fuel cell,and ultracapacitor bank with nonlinear loads
Authors:Mohsen Aryan Nezhad  Hassan Bevrani
Affiliation:Smart/Micro Grid Research Center, Department of Electrical & Computer Engineering, University of Kurdistan, Sanandaj, Iran
Abstract:The nonlinear loads create a wide range of current harmonics in the system. Such loads can make distortions on the output voltage profile, influence on the fuel cell (FC) performance, and endanger safe operation of the FC unit. In this paper, new strategies for power-following and AC voltage control have been developed. The proposed system consists of the ultracapacitor (UC) bank and proton exchange membrane fuel cell (PEMFC) supplying nonlinear AC loads. The power tracking strategy is based on the Fourier analysis of total load demand. The Fourier analysis is used as an effective tool to eliminate destructive effect of current harmonics on the PEMFC output current. To supply the nonlinear AC loads under sinusoidal voltage with the fast response, a dynamic model for the inverter control loop is also presented. This model is used to enhance the input reference tracking and reject input/output disturbances. The simulation outcomes confirm the desirable PEMFC performance against nonlinear load disturbances. In addition, the output AC voltage is kept sinusoidal and has low deviations under nonlinear load variations.
Keywords:Proton exchange membrane fuel cell  Anode and cathode pressures  Load-following  Nonlinear load  Ultracapacitor
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号