摘    要:对鱼米滩水电站1号发电机组空载启动时出现的定子绕组过电压故障进行了分析,指出高次谐波谐振是导致过电压的主要原因,提出了解决该问题的方法和措施。

关 键 词:水轮发电机组  定子绕组  绝缘介质  过电压  故障分析  故障处理  鱼米滩水电站

Over-Voltage Fault Analysis and Treatment of Generator #1 in Yumitan Hydroelectric Power Station
Zhang Lingpeng ,Ma Shiying.Over-Voltage Fault Analysis and Treatment of Generator #1 in Yumitan Hydroelectric Power Station[J].Hunan Electric Power,2003,23(2):45-46.
Authors:Zhang Lingpeng  Ma Shiying
Affiliation:Zhang Lingpeng 1,Ma Shiying 2
Abstract:The stator winding over voltage fault of generator #1 in Yumitan hydroelectric power station under no load starting is analysed in the paper. It is pointed out that the over voltage fault is the result of high order harmonic resonance. The methods and measures should be taken are presented.