Failure Analysis of a Copper Tube for Pneumatic System
Authors:L S Araujo  L H de Almeida  D A Pereira
Affiliation:1. PEMM/COPPE-Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
2. MetroRio, Rio de Janeiro, Brazil
Abstract:Deoxidized-high-phosphorous (DHP) copper tubes are widely and successfully used in different applications as: water distribution, air-conditioning, solar heating, fuel, oil, and natural gas services and compressed air systems. In the present analysis, a failure of a copper tube composing a pneumatic system of a subway train was investigated by means of on-site examination, metallographic and fracture analyses. Results show that arcs coming from an exposed power cable lead to partial melting of a section of the tube, resulting in loss of pressure and interruption of the train.