电站锅炉引风机振动原因分析及处理
引用本文:李玉山.电站锅炉引风机振动原因分析及处理[J].流体机械,2009,37(7).
作者姓名:李玉山
作者单位:秦皇岛职业技术学院,河北秦皇岛,066100
摘    要:概述了秦皇岛热电厂3号炉2台引风机进行提高功率的技术改造后, 高速运行时存在的振动问题;分别叙述了振动现状测试、气流激振试验及振动变化观察试验情况;分析了振动原因,提出了处理措施, 得出了处理效果良好的结论.

关 键 词:离心式引风机  振动  试验

Cause Analysis and Treatment of Power Plant Boiler Fan Vibration Modified
LI Yu-shan.Cause Analysis and Treatment of Power Plant Boiler Fan Vibration Modified[J].Fluid Machinery,2009,37(7).
Authors:LI Yu-shan
Affiliation:Qinhuangdao Vocational & Technical College;Qinhuangdao 066100;China
Abstract:Vibration problems when operating at a high speed after 2 induced draft fans of No.3 boiler in Qinhuangdao power plant are described.The vibration statusmeasurement,gas flow activation test and vibration change observational test coditions are separately described.The vibration reasons are analyzed,the treatment measures are provided,and good treatment result conclusions are obtained.
Keywords:centrifugal induced draft fan  vibration  test