首页 | 本学科首页   官方微博 | 高级检索  
     

轻武器光学瞄具的视差参数测试
引用本文:于秋水,安志勇,杨瑞宁,梁爽,宋静怡. 轻武器光学瞄具的视差参数测试[J]. 光学精密工程, 2010, 18(8): 1732-1737. DOI: 10.3788/OPE.20101808.1732
作者姓名:于秋水  安志勇  杨瑞宁  梁爽  宋静怡
作者单位:长春理工大学,光电工程学院,吉林,长春,130022;空军航空大学,基础部,吉林,长春,130022;长春理工大学,光电工程学院,吉林,长春,130022;山东临沂师范学院,山东,临沂,276005;吉林大学,电子科学与工程学院,吉林,长春,130012
基金项目:总装十一五预研基金资助项目 
摘    要:在对传统的视差测量方法进行充分研究的基础上,提出了基于自动调焦技术的轻武器光学瞄具的视差参数测试方法。介绍了自动调焦技术的工作原理及其系统组成框图;根据轻武器瞄具性能指标的具体要求,结合自动调焦技术设计了一套轻武器瞄具的视差参数测试系统,并介绍了被测瞄具放入该测试系统前后的自动调焦过程;最终通过求取视度之差得到视差。根据轻武器瞄具光学系统的实际测试要求进行了5次测试实验,并对这5次实验数据进行了分析。结果表明:视差测试精度为0.0296m-1,达到了轻武器光学瞄具技术指标0.1m-1的要求,保证了测量精度。

关 键 词:轻武器  光学瞄具  自动调焦  视差测试
收稿时间:2009-06-23
修稿时间:2009-10-26

Test of parallax parameters for optoelectronic sights in small arms
YU Qiu-shui,AN Zhi-yong,YANG Rui-ning,LIANG Shuang,SONG Jing-yi. Test of parallax parameters for optoelectronic sights in small arms[J]. Optics and Precision Engineering, 2010, 18(8): 1732-1737. DOI: 10.3788/OPE.20101808.1732
Authors:YU Qiu-shui  AN Zhi-yong  YANG Rui-ning  LIANG Shuang  SONG Jing-yi
Affiliation:1. College of Electronics &; Information Engineering, Changchun University of Science and Technology,Changchun 130022,China;;2. Fundamental Department,Aviation University of Air Force,Changchun 130022,China;;3. Linyi Normal University,Linyi 27600,China;;4. College of Electronics Science &; Engineering,Jilin University,Changchun 130012,China
Abstract:According to the research of traditional parallax measuring techniques, a parameter test method based on the auto-focus technology was proposed, and the principle of auto-focus and its composition block diagram were introduced. Then, in consideration of the specific requirements of small arms for sight performance, a parallax test system was designed combined with the auto-focus technology and the auto-focus processes before or after the measuring sight placed in the test system were described in detail. Furthermore, the parallax parameters were obtained according to the difference of diopter. Five experiments were performed on the requirements of the actual optical system, and the obtained parallax parameters were analyzed. Results show that the measurement accuracy of parallax parameters is 0.029 6 m-1, which achieves the technical specification less than 0.1 m-1 and guarantees the measuring accuracy.
Keywords:small arm  optoelectronic sight  auto-focusing  parallax test
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《光学精密工程》浏览原始摘要信息
点击此处可从《光学精密工程》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号