摘    要:针对300MW汽轮发电机励磁电刷及滑环的典型故障情况,从电刷性能、运行条件、配套设备状况及运行维护等方面进行了详细分析,进而提出了防止电刷损坏的措施。

关 键 词:励磁电刷  典型故障  原因  措施
文章编号:1671-0320(2006)01-0030-04
修稿时间:2005年4月18日

Analysis and Countermeasures about Excitaion Brush Failure oF 300 MW Steam Turbine Generator
ZHAO Li-fen,JIA Yu-kang.Analysis and Countermeasures about Excitaion Brush Failure oF 300 MW Steam Turbine Generator[J].Shanxi Electric Power,2006(1):30-33.
Authors:ZHAO Li-fen  JIA Yu-kang
Abstract:This paper analysis the actuality of the excitation brush's and slip typical fault of the 300 MW steam turbine generator in the brush performance,running condition,support equipments and maintenance work.Furthermore it gives out the countermeasure to prevent the brush failure.And the conclusion could partly direct production pracice.