Conductor and joint test results of JT-60SA CS and EF coils using the NIFS test facility
Affiliation:1. National Institutes for Quantum Science and Technology, Naka, Ibaraki, Japan;2. Fusion for Energy, Garching, Munich, Germany;3. Toshiba Energy Systems & Solutions Corporation, Yokohama, Kanagawa, Japan
Abstract:In 2007, JAEA and NIFS launched the test project to evaluate the performance of cable-in-conduit (CIC) conductors and conductor joints for the JT-60SA CS and EF coils. In this project, conductor tests for four types of coil conductor and joint tests for seven types of conductor joint have been conducted for the past eight years using the NIFS test facility. As a result, the test project indicated that the CIC conductors and conductor joints fulfill the design requirement for the CS and EF coils. In addition, the NIFS test facility is expected to be utilized as the test facility for the development of a conductor and conductor joint for the purpose of the DEMO nuclear fusion power plant, provided that the required magnetic field strength is within 9 T.
Keywords:JT-60SA  Cable-in-conduit (CIC) conductor  Current sharing temperature (Tcs) measurement  Joint resistance measurement  Test facility