首页 | 本学科首页   官方微博 | 高级检索  
     

离子色谱仪测定工业循环水中阴离子含量
引用本文:童玲,李月霞. 离子色谱仪测定工业循环水中阴离子含量[J]. 山东化工, 2009, 38(12): 43-45
作者姓名:童玲  李月霞
作者单位:兰州石化公司质检部,甘肃,兰州,730060
摘    要:采用化学抑制-电导-离子色谱法测定工业循环水中阴离子,以3.5mmol/L Na2CO3、1mmol/L NaHCO3为淋洗液。18.2mol/L H2SO4为再生液,流速1.2ml/min,5种阴离子在10.13min完成检测。各离子的检出限0.01~0.5mg/L,本法精密度小于2%,线性范围较宽,水样中各阴离子的平均加标回收率92.63%~103.57%。该法适合工业循环水中阴离子含量测定。

关 键 词:离子色谱  工业循环水  阴离子  含量

Determination of Five Anions in Industrial Recycled Water by Ion Chromatography
TONG Ling,LI Yue-xia. Determination of Five Anions in Industrial Recycled Water by Ion Chromatography[J]. Shandong Chemical Industry, 2009, 38(12): 43-45
Authors:TONG Ling  LI Yue-xia
Affiliation:TONG Ling, LI Yue - xia(Quality Inspection Department of Lanzhou Petrochemical Company, Lanzhou 730060, China)
Abstract:The chemically suppressed conductivity detection and ion chromatography were used to detect the content of five anions in industrial recycled water. They were separated simultaneously with a mixed solution of 3.5mmol/L Na2CO3 and lmmol/L NaHCO3 as absorbing solution, and 18.2 mol/L H2SO4 as regenerate solution. The samples were analyzed at the flow rate of 1.2mL/min, and were detected directly by conductimetric detector in 10. 13 minutes. Under the optimized condition,the detection limits for five analytes were from 0.01 to 0.5mg/L, RSD of the results were less than 2% ,The linear ranges were wide, average recoveries for five inorganic anions were between 92.63% - 103.57%. The method was suitable to determine the content of inorganic anions in industrial recycled water.
Keywords:ion chromatography  industrial recycled water  inorganic anion  content
本文献已被 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号