首页 | 本学科首页   官方微博 | 高级检索  
     

Formation of Vacancy-Type Dislocation Loops in Hydrogen-Ion-Implanted Fe–Cr Alloy
基金项目:the National Natural Science Foundation of China
摘    要:Fe-10 at.%Cr alloy was implanted with hydrogen ions at room temperature, followed by annealing at high temperatures.The annealing process made the defects develop into large dislocation loops. The nature of the dislocation loops formed after annealing was studied by the evolution of loops under in situ electron irradiation in high-voltage electron microscope.It indicated that only interstitial-type loops were observed when annealed at 550 °C and below, but vacancy-type loops started to form at the temperature higher than 600 °C. According to the previous study of our group, the presence of chromium element made the formation temperature of vacancy-type loops higher than that in pure iron. The effect of alloying elements on the formation temperature of the vacancy-type loops was discussed.

收稿时间:2018-06-19

Formation of Vacancy-Type Dislocation Loops in Hydrogen-Ion-Implanted Fe-Cr Alloy
Yu-Feng Du,Li-Juan Cui,Wen-Tuo Han,Fa-Rong Wan. Formation of Vacancy-Type Dislocation Loops in Hydrogen-Ion-Implanted Fe-Cr Alloy[J]. Acta Metallurgica Sinica(English Letters), 2019, 32(5): 566-572. DOI: 10.1007/s40195-018-0807-4
Authors:Yu-Feng Du  Li-Juan Cui  Wen-Tuo Han  Fa-Rong Wan
Affiliation:1.Department of Materials Physics and Chemistry, School of Materials Science and Engineering, University of Science and Technology, Beijing, Beijing 100083, China
Abstract:Fe-10 at.%Cr alloy was implanted with hydrogen ions at room temperature, followed by annealing at high temperatures. The annealing process made the defects develop into large dislocation loops. The nature of the dislocation loops formed after annealing was studied by the evolution of loops under in situ electron irradiation in high-voltage electron microscope. It indicated that only interstitial-type loops were observed when annealed at 550 °C and below, but vacancy-type loops started to form at the temperature higher than 600 °C. According to the previous study of our group, the presence of chromium element made the formation temperature of vacancy-type loops higher than that in pure iron. The effect of alloying elements on the formation temperature of the vacancy-type loops was discussed.
Keywords:Hydrogen implantation  Interstitial-type loops  Vacancy-type loops  Fe-Cr alloy  High-voltage electron microscope  
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《金属学报(英文版)》浏览原始摘要信息
点击此处可从《金属学报(英文版)》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号