Authors:I. O. Orobei  I. F. Kuz'mitskii  D. A. Grinyuk  S. E. Zharskii  V. V. Saroka  M. V. Maksimova
Affiliation:(1) Belarussian State Technological University, ul. Sverdlova 13-A, Minsk, 220050, Belarus
Abstract:An induction meter based on a Hall-effect transducer with in-phase signal suppression and thermostabilization circuits is described. It is powered by a 103-Hz ac line. The maximum relative error in temperature measurements from 0 to 70°C does not exceed 0.7 % for magnetic fields of 50–100 mgrT, 0.4% for 0.1–1 mT, and 0.1% for 1–625 mT. In the range of 50–500 mgrT, the error is determined by an in-phase signal. The contribution of the total temperature error is le0.01% per 50°C. Depending on the induction of the measured magnetic field, the resolution changes from 0.12 to 19 mgrT.