摘    要:采用氢化物发生原子荧光光谱法测定水中痕量锑。用盐酸和5%硫脲+5%抗坏血酸混合溶液处理样品,并以1.0%硼氢化钾和0.5%氢氧化钾为还原剂,在5%的盐酸介质中测定锑,锑的检出限(DL)为:0.028μg/L,相对标准偏差RSD(n=15)为3.1%,水样的加标回收率在94.3%~103.6%之间。本方法具有操作简便、快速、基体干扰少、灵敏度高和重现性好等优点,可用于水样中锑的测定。

关 键 词:氢化物发生  原子荧光光谱法    

HG-AFS Determination Of Trace Amounts Of Antimony in Water
Yang Jingde. HG-AFS Determination Of Trace Amounts Of Antimony in Water[J]. Chemical Engineering & Equipment, 2010, 0(8): 188-189,249
Authors:Yang Jingde
Affiliation:Yang Jingde(Quannan Water Supply Co.Ltd Quanzhou,Fujian,362000,China)
Abstract:HG-AFS was applied to the determination of trace amounts of antimony in water.The water sample was treated by HCL and 5% Thiourea(H2NSCNH2)~5% Ascorbic acid(C6H8O6).The method is based on the reaction of antimony(Sb) with KBH4 to form the hydride gas in medium of 5% HC1.The detection limits(DL) are 0.028μg/L.and it is RSD(n=15)found was 3.1%,the recoveries of Sb obtained by standard addition method are in the ranges of 94.8%~102.3%.The method is simple,rapid,less matrix interference and high sensitivity and reproducible.It can be applied to determination of Sb in water.
Keywords:Hydride generation  Atomic fluorescence spectrometric  Antimony  Water