Neodymium(III) cathodic processes in molten fluorides |
| |
Authors: | C. Hamel P. Chamelot |
| |
Affiliation: | a CEA/DEN/VRH/DRCP/SCPS/LPP, Site de Marcoule, Bâtiment 399, BP 17171, 30207 Bagnols sur Cèze, Cedex, France b Laboratoire de Génie Chimique UMR 5503, Université Paul Sabatier, 118 route de Narbonne, 31062 Toulouse, Cedex 04, France |
| |
Abstract: | The electrochemical behaviour of the Nd(III)/Nd(0) system has been investigated in several molten media and more particularly in LiF-CaF2. A preliminary study based both on thermodynamic and experimental data showed that it is not possible to observe the Nd(III)/Nd(0) system in LiF-KF and LiF-NaF melts; because the K+ and Na+ cation reduction waves hide the Nd3+ reduction wave. Then, the Nd(III)/Nd(0) system has been investigated at 810 °C using solutions of NdF3 in fluoride solvents without K+ and Na+ ions, such as LiF-CaF2, by cyclic voltammetry, chronopotentiometry and square wave voltammetry. Experimental results show that neodymium trifluoride is reduced in Nd(0) in a one-step process exchanging three electrons (Nd(III) + 3e− → Nd(0)). The electrode process is shown to be diffusion controlled. Nd(III) diffusion coefficient is in the range of 1.1-1.3 × 10−5 cm2 s−1 at 810 °C. |
| |
Keywords: | Neodymium Molten Fluorides Electrowining Chronopotentiometry Voltammetry |
本文献已被 ScienceDirect 等数据库收录! |
|