首页 | 本学科首页   官方微博 | 高级检索  
     

1000t/h锅炉轴流式风机机械故障原因分析
引用本文:尹民权.1000t/h锅炉轴流式风机机械故障原因分析[J].沈阳电力高等专科学校学报,2008(3):210-214.
作者姓名:尹民权
作者单位:华电国际山东邹县发电厂生产技术部,山东邹县273522
摘    要:华电国际山东邹县发电厂自投产以来,4台锅炉的送、引风机先后发生了各种不同的故障,经过不断的改进、治理,取得了一定的成果.着重介绍了SAF28-18-16-1型轴流式动叶可调引风机安装、维修过程中存在的问题,以及引风机运行中出现机械故障的状态诊断、原因分析及处理.通过分析探讨找出原因和应注意的问题.

关 键 词:锅炉引风机  故障诊断  分析探讨

Mechanical fault .cause analysis of axial flow fan in 1 000 t/h boiler
YIN Min-quan.Mechanical fault .cause analysis of axial flow fan in 1 000 t/h boiler[J].Journal of Shenyang Electric Power Institute,2008(3):210-214.
Authors:YIN Min-quan
Affiliation:YIN Min-quan ( Production Technology Office, Shandong Zouxian Power Plant, Zoucheng 273522, China)
Abstract:Different faults that occurred in forced-draft fan and induced-draft fan of four boilers since commissioning were improved and processed and certain achievements were made. The emphasis of this article is on the problems in installation and maintenance of 8AF28-18-16-1 adjustable-blade axial-flow draft fan, the mechanical fault diagnosis, reason analysis and procession. The cause and future attentions are found by analysis and discussion.
Keywords:boiler's induced-draft fan  fault diagnosis  analysis and discussion
本文献已被 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号