摘    要:以目前在运变压器常用的25#绝缘油为例,测试了不同温度条件下变压器油在电极针产生的电场下的点燃特性,为变压器起火机理与防治研究提供指导。试验表明,25#变压器油在电火花能量18 J、最大电场强度为6.56×103 kV/m的针-针电极电场条件下,点燃的临界温度约为172 ℃;其引燃有爆燃和稳定燃烧2个过程,爆燃时燃烧瓶内压力最大,为510 kPa左右,其引燃过程与单一气体组分丁烷有较大差异。

关 键 词:绝缘油  电极针  电场  引燃  温度特性  

Ignition temperature characteristics oftransformer oil under the influence of electric field
LIU Yu,WU Chuan-ping,CHEN Bao-hui,ZHOU Tian-nian.Ignition temperature characteristics oftransformer oil under the influence of electric field[J].Fire Science and Technology,2021,40(8):1118-1120.
Authors:LIU Yu  WU Chuan-ping  CHEN Bao-hui  ZHOU Tian-nian
Affiliation:State Key Laboratory of Disaster Prevention & Reduction for Power Grid Transmission and Distribution Equipment (State Grid Hunan Electric Power Corporation Disaster Prevention & Reduction Center), Hunan Changsha 410007, China
Abstract:This paper takes the 25# insulating oil which is commonly used in current transformers as an example to test the ignition characteristics under the electric field generated by the electrode needles under different temperature conditions, and the ignition temperature characteristics of transformer oil under specified conditions are obtained, which can provide guidance for transformer fire mechanism and prevention research. The test results show that the critical temperature of ignition of the  25# insulating oil is about 172 ℃, under the condition of needle electrode electric field, with maximum electric field 6.56×103 kV/m, and intensity spark energy 18 J. There are two ignition processes: deflagration and stable combustion. During deflagration, the maximum pressure in the combustion bottle is about 510 kPa, which is quite different from butane.
Keywords:nsulating  oil  electrode needle  electric field  ignition  temperature characteristics  
本文献已被 CNKI 等数据库收录!
点击此处可从《消防科学与技术》浏览原始摘要信息
点击此处可从《消防科学与技术》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号