An experimental study on a modified air conditioner with a domestic hot water supply (ACDHWS) |
| |
Authors: | Huimin Jiang Yiqiang JiangYang Wang Zuiliang MaYang Yao |
| |
Affiliation: | Department of Building Thermal Engineering, Harbin Institute of Technology, Box 2651, Harbin 150090, China |
| |
Abstract: | The recovery of condenser heat in air conditioners is attractive because of its great economy and environmental value. This work experimentally studies a modified air conditioner with a domestic hot water supply (ACDHWS) that operates in the space-cooling and water-heating mode. The working principles and the basic features of the ACDHWS are introduced in this paper. This is followed by an experimental study on dynamic operation characteristics, hot water supply performance, energy efficiency and the temperature distribution of hot water in the storage tank of the unit. The results show that the ACDHWS can reliably be used to heat domestic hot water without losing its cooling capacity when it is controlled well in different operation conditions. Comparatively, the coefficient of comprehensive energy performance (COP2) of the ACDHWS is about 38.6% higher than that of the original unit. Furthermore, it is proved that the ACDHWS can continuously supply hot water for householders if a suitable hot water storage tank is installed. All these may be much helpful to develop a perfect ACDHWS product. |
| |
Keywords: | Experiments Air conditioners Domestic hot water supply Condenser heat recovery Energy-saving |
本文献已被 ScienceDirect 等数据库收录! |