首页 | 本学科首页   官方微博 | 高级检索  
     

栓钉连接双钢板-混凝土组合剪力墙抗剪性能数值分析
引用本文:韦芳芳,朱有华,喻君. 栓钉连接双钢板-混凝土组合剪力墙抗剪性能数值分析[J]. 土木与环境工程学报, 2021, 43(1): 96-106
作者姓名:韦芳芳  朱有华  喻君
作者单位:河海大学 土木与交通学院, 南京 210098
基金项目:National Natural Science Foundation of China (No.51608168); Fundamental Research Funds for the Central Universities (No. 2017B16014, 2019B12814).
摘    要:双钢板-混凝土组合剪力墙结构是一种新型高层建筑抗侧力构件,具有良好的应用价值和发展前景.根据其他学者的试验结果,结合相关文献中连接件的剪切滑移公式,拟合得出抗剪栓钉的剪力-滑移关系,并通过有限元软件ANSYS建立了双钢板-混凝土组合剪力墙的有限元模型.以分析组合剪力墙的剪切性能为目的,采用相关假定简化模型并与已有试验结...

关 键 词:组合剪力墙  剪力连接件  抗剪性能  数值分析  组合结构
收稿时间:2019-05-20

Numerical analysis of shear resistance of concrete filled double-steel-plate composite walls with shear stud connectors
WEI Fangfang,ZHU Youhu,YU Jun. Numerical analysis of shear resistance of concrete filled double-steel-plate composite walls with shear stud connectors[J]. Journal of Civil and Environmental Engineering, 2021, 43(1): 96-106
Authors:WEI Fangfang  ZHU Youhu  YU Jun
Affiliation:College of Civil and Transportation Engineering, Hohai University, Nanjing 210098, P. R. China
Abstract:The concrete filled double steel plate composite wall (CFDSPCW) with shear stud connectors is a new type of construction component for high-rise buildings that resist lateral force. In this paper, the in-plane shear resistance of CFDSPCWs is studied with nonlinear finite element analysis using ANSYS. To this end, some assumptions were made to simplify the numerical model. Based on the experimental results and the formula of shear-slip of stud connectors in the literature, a constitutive relationship explaining the shear-slip of shear stud connectors is proposed using curve fitting. Then, the finite element model of the experimental CFDSPCW is established and validated through experimental results. Thereafter, the study presents the effects of key parameters including the space of stud connectors, the thickness of both the steel plate and concrete core, the concrete strength, and the span-depth ratio of walls on the shear resistance of CFDSPCWs. The results indicate that the thickness of both the steel plate and the concrete core, and the strength of concrete are the most critical factors affecting the shear resistance of CFDSPCWs, and the spacing of stud connectors affects the failure mode of CFDSPCWs.
Keywords:composite wall  shear connectors  shear resistance  numerical analysis  composite structures
点击此处可从《土木与环境工程学报》浏览原始摘要信息
点击此处可从《土木与环境工程学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号