首页 | 本学科首页   官方微博 | 高级检索  
     


Design of a high-temperature and high-pressure liquid flow cell for x-ray absorption fine structure measurements under catalytic reaction conditions
Authors:Kawai Toshihide  Chun Wang-Jae  Asakura Kiyotaka  Koike Yuichiro  Nomura Masaharu  Bando Kyoko K  Ted Oyama S  Sumiya Hitoshi
Affiliation:Catalysis Research Center, Hokkaido University, Kita 21-10, Kita-ku, Sapporo 001-0021, Japan.
Abstract:The design and performance of a new high-pressure and high-temperature cell for measurement of x-ray absorption fine structure (XAFS) spectra of solid catalysts working in a flowing liquid are presented. The cell has flat, high-purity sintered cubic boron nitride (c-BN) windows which can tolerate high temperature (900 K) and high pressure (10 MPa). The c-BN is a new material which has the highest tensile strength, second only to diamond, and is also chemically and thermally stable. The use of the cell is demonstrated for measurements of PtPdAl(2)O(3) and Ni(2)PSiO(2) hydrodesulfurization catalysts at reaction conditions. A technique called delta chi (Deltachi), involving determining the difference between XAFS spectra of the sample at reaction conditions and the bare sample, is introduced.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏