首页 | 本学科首页   官方微博 | 高级检索  
     

水泵水轮机低水头发电空载稳定性调试实践
引用本文:周杰,沈剑初,周攀.水泵水轮机低水头发电空载稳定性调试实践[J].西北水电,2012(Z1):78-80.
作者姓名:周杰  沈剑初  周攀
作者单位:1. 中国水电顾问集团华东勘测设计研究院,杭州,310014
2. 国网电力科学研究院/南京南瑞集团公司,南京,210003
摘    要:基于某抽水蓄能电站发电空载工况稳定性调试实践,验证了水泵水轮机尝试调节导叶开启速度以实现发电空载稳定并网的可行性,为解决水泵水轮机空载稳定运行提供了实例.

关 键 词:水泵水轮机  发电空载  并网  稳定

Practice on Test of Stability of Pump Turbine Operation with No-load at Low Head
ZHOU Jie , SHEN Jian-chu , ZHOU Pan.Practice on Test of Stability of Pump Turbine Operation with No-load at Low Head[J].Northwest Water Power,2012(Z1):78-80.
Authors:ZHOU Jie  SHEN Jian-chu  ZHOU Pan
Affiliation:1.HYDROCHINA Huadong Engineering Corporation,Hangzhou 310014,China; 2 State Grid Electric Power Research Institute/Nanjin Nanri Group Company,Nanjin 210003,China)
Abstract:In accordance with practice on test of operation stability of a pumped storage power station with no-load,feasibility of stable grid interconnection of pump turbine operation with no-load through adjustment of the opening speed of wicket gates is verified.This provides practice of the stable operation of pump turbine with no-load.
Keywords:Pump turbine  power generation with no-load  grid interconnection  stability