摘    要:冷却水水质欠佳、进气温度偏高和换热面积偏小造成UF-2700/7型预冷机换热效率低,制约了空分设备的正常生产。采取更换冷凝器和改善冷却水质量等改造措施,提高了预冷机的工作效率。

关 键 词:小型空分设备  预冷机  换热效率

Technique modification of UF-2700/7 type precooler
Wang Shuo-ren.Technique modification of UF-2700/7 type precooler[J].Cryogenic Technology,2006(4).
Authors:Wang Shuo-ren
Abstract:A low heat exchange efficiency of UF-2700/7 type precooler was caused by low-quality cooling water, high temperature of inlet gas and insufficient heat exchange area, which limited the operation of air separation unit. After some corresponding measures and technical modifications were carried out, the efficiency of the precooler has been improved.