首页 | 本学科首页   官方微博 | 高级检索  
     

离子膜电解槽闪爆事故的分析
引用本文:王照民.离子膜电解槽闪爆事故的分析[J].中国氯碱,2003(11):42-44.
作者姓名:王照民
作者单位:开封东大化工集团离子膜分厂,河南,开封,475003
摘    要:通过对离子膜电解槽停车泄料时发生的闪爆事故的分析,找出引起闪爆事故的主要原因是由漏入的氯气和氢气在A槽阳极室内达到爆炸极限后遇到尖端的放电造成的电火花所致。同时分析了A槽槽电压升高的原因,介绍了预防事故发生的措施。

关 键 词:离子膜  电解槽  闪爆事故  事故分析  氯碱工业  事故预防
修稿时间:2003年7月7日

Analysis of ionic exchange membrane electrolyzer flash explosion accident
WANG Zhao- min.Analysis of ionic exchange membrane electrolyzer flash explosion accident[J].China Chlor-Alkali,2003(11):42-44.
Authors:WANG Zhao- min
Abstract:The explosion accidental causes was given by analyzing the ionic membrane electrolyzer flash accident, which took place when the unit was stopped to blow down materials. It is pointed that when the chlorine gas leaking in and hydrogen gas in the anode chamber of electrolyzer A reaches the explosion limit, the electric spark stemming from top discharge will arise the accident. Meanwhile, the causes of electrolyzer A's voltage arising was analyzed, and some preventive measures was mentioned.
Keywords:ionic exchange membrane electrolyzer  flash explosion accident  preventive measures