首页 | 本学科首页   官方微博 | 高级检索  
     

浅析泵站接地存在问题及对策
引用本文:李亚洲,过永生,刘伟.浅析泵站接地存在问题及对策[J].水利与建筑工程学报,2010,8(6).
作者姓名:李亚洲  过永生  刘伟
摘    要:详细分析了泵站接地装置在实际工作中存在问题,引起雷击时避雷器不动作,造成用电设备损坏等现象,提出了防腐、降阻、设水下接地网等处理措施,以及在电气设计时,从材料选择、接地网的布置方式采取的措施,保证泵站接地的安全性、可靠性,确保人身和设备的安全。

关 键 词:接地网  接地装置  对策  泵站

Primary Analysis on Existed Problems and Countermeasures for Grounding Equipment of Pumping Station
LI Ya-zhou,GUO Yong-sheng,LIU Wei.Primary Analysis on Existed Problems and Countermeasures for Grounding Equipment of Pumping Station[J].Journal of Water Resources Architectural Engineering,2010,8(6).
Authors:LI Ya-zhou  GUO Yong-sheng  LIU Wei
Abstract:The existed problems for grounding equipment of pumping stations in practical work are analyzed here,which would cause the lightning arrester not to operate,resulting in damages of electrical equipments.Based on this,the treatment measures are put forward such as the preserving,resistance reducing and locating underwater grounding network.At the same time,the measures are taken from material selection and grounding network layout in electrical design,so as to ensure the safety and reliability of grounding,as well as the safety of persons and equipments.
Keywords:grounding network  grounding equipment  countermeasures  pumping station