首页 | 本学科首页   官方微博 | 高级检索  
     

设置加劲肋的双层钢板-混凝土组合剪力墙抗震性能试验研究
引用本文:汤序霖,丁昌银,左志亮,蔡健,何炳泉,郑旭东. 设置加劲肋的双层钢板-混凝土组合剪力墙抗震性能试验研究[J]. 建筑结构学报, 2017, 38(5): 85-91
作者姓名:汤序霖  丁昌银  左志亮  蔡健  何炳泉  郑旭东
作者单位:1. 华南理工大学 土木与交通学院, 广东广州 510640; ;2. 广州机施建设集团有限公司, 广东广州 510115;3. 华南理工大学 亚热带建筑科学国家重点试验室, 广东广州 510640
基金项目:国家自然科学基金青年基金项目(51408230),广东省自然科学基金项目(2016A030310418),广州市科技计划项目(201604010053)
摘    要:为研究设置加劲肋的双层钢板-混凝土组合剪力墙的抗震性能,对5个试验轴压比为0.4的模型试件进行了恒轴力下的拟静力试验。通过改变加劲肋、中部钢管混凝土暗柱的布置形式,研究该组合剪力墙在水平反复荷载作用下的破坏机理、滞回性能、变形能力以及耗能能力。试验结果表明:试件破坏时底部墙体钢板均发生了屈曲,呈现典型的压弯破坏特征;试件具有良好的延性和耗能能力;在双层钢板-混凝土组合剪力墙中仅设置纵向加劲肋对承载力提高不明显,仅设置横向加劲肋可以略提高试件的承载力,而双向加劲肋的设置将较明显提高试件的承载力;在双层钢板-混凝土组合剪力墙中部增设钢管混凝土暗柱可以较为明显地改善试件的承载力与延性。

关 键 词:加劲肋  抗震性能  拟静力试验  双层钢板  组合剪力墙  

Experimental research on seismic behavior of composite shear wall with double steel plates and infill concrete with stiffeners
TANG Xulin,DING Changyin,ZUO Zhiliang,CAI Jian,HE Bingquan,ZHENG Xudong. Experimental research on seismic behavior of composite shear wall with double steel plates and infill concrete with stiffeners[J]. Journal of Building Structures, 2017, 38(5): 85-91
Authors:TANG Xulin  DING Changyin  ZUO Zhiliang  CAI Jian  HE Bingquan  ZHENG Xudong
Abstract:In order to study the seismic behavior of composite shear wall with double steel plates and infill concrete with stiffeners, the quasi-static experiment under constant axial load on five specimens was carried out. The testing axial compression ratio was 0.4. The parameters in the experiment included the forms of stiffening rib and setting the concrete filled steel tubular column in central of the specimens. The failure mechanism, hysteretic behavior, deformability and energy dissipation capacity of the specimens under a cyclic lateral load were analyzed. The experiment results show that local buckling occurs at the lower part of the specimens before failure, and the failure mode of specimens is a typical compression-bending failure. The specimens have good bearing capacity, deformability and energy dissipation. There is no increase of bearing capacity for composite shear wall with transverse stiffener, but a little increase for that with longitudinal stiffener, and significantly increase for that with both longitudinal and transverse stiffeners. The deformability and bearing capacity of the composite shear wall can be significantly improved by setting the concrete filled steel tubular columns in center of the specimens.
Keywords:composite shear wall  double steel plates  quasi-static experiment  seismic behavior  stiffener  
本文献已被 CNKI 等数据库收录!
点击此处可从《建筑结构学报》浏览原始摘要信息
点击此处可从《建筑结构学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏