基金项目:中国博士后科学基金项目(2015M580991),中央高校基本科研业务费专项资助(FRF-TP-15-104A1)
摘    要:结合GB 50009-2012《建筑结构荷载规范》中的等效静风荷载计算方法,研究设置主被动可切换的混合调谐质量阻尼器(TMD/ATMD)的规则高层建筑结构的风振分析与实用设计方法。将控制系统的风振控制效果按照风振响应方差相等的原则归结为对受控结构的附加等效阻尼比,推导了控制系统最优参数和附加等效阻尼比的计算公式,给出了惯性质量平均最大行程比、主动控制力和额定功率的简化计算方法;并讨论了主动/被动控制模式的切换准则。最后给出以风振控制Benchmark结构模型为对象的受控结构及混合调谐质量阻尼系统的设计算例。算例分析表明:建议的设计方法可以方便地进行受控结构响应分析和控制系统参数设计;混合调谐质量阻尼器可以有效减小设计等效静风荷载和结构的动力响应。

关 键 词:高层建筑  调谐质量阻尼器  风振控制  混合控制  等效阻尼比  

Design method for wind-induced vibration control of high-risebuildings with hybrid tuned mass dampers
XU Huaibing,OU Jinping. Design method for wind-induced vibration control of high-risebuildings with hybrid tuned mass dampers[J]. Journal of Building Structures, 2017, 38(6): 144-154
Authors:XU Huaibing  OU Jinping
Affiliation:1. Department of Civil Engineering, University of Science and Technology Beijing, Beijing 100083, China;2. Key Lab of Structures Dynamic Behavior and Control of China Ministry of Education, Harbin Insititute of Technology, Harbin 150090, China;3. School of Civil Engineering, Harbin Institute of Technology, Harbin 150090, China
Abstract:Based on the calculation method of wind loads in Chinese design code GB 50009—2012 ‘Load code for the design of building structures’, the practical design method for wind-induced vibration control of regular high-rise buildings with active/passive switchable hybrid tuned mass dampers (TMD/ATMD) was proposed. According to the equivalence of the vibration response variance, the control effect of TMD/ATMD system on the structure was attributed into the additional damping ratio. The formulas of the optimal parameters and the additional equivalent damping ratios were derived. The simplified calculation methods of average stroke ratio of inertial mass, active control force, rated power of the driver were proposed and the control modes switching criteria were discussed. Finally, this method was applied in wind-resistant design of the benchmark structural model controlled with TMD/ATMD system. The case study shows that the proposed design method can be used to analyze the response of the controlled structure and the preliminary design of the control system. Hybrid tuned mass damper can effectively reduce the equivalent static wind loads and dynamic response of the structure.
Keywords:high-rise building  hybrid tuned mass damper  wind-induced vibration control  hybrid control  equivalent damping ratio  