摘    要:通过对两起电网直流故障事件的分析,发现火电燃煤机组一次调频动态响应特性普遍不佳,电网大频差与中小频差特性完全不同。在对电网大频差模型辨识的基础上,优化机组一次调频控制策略,实施大频差试验,分析梳理试验结果,评估机组各工况点风险,对火电燃煤机组大频差一次调频性能进行全面客观评价,借此在确保机组安全运行前提下,有效提升一次调频性能,最终达到网源双赢的目的。

关 键 词:燃煤发电机组  大频差  一次调频  模型辨识  控制策略  优化  风险评估  
收稿时间:2016-06-02

Research and Optimization on Primary Frequency Regulation Characteristics with Large Frequency Deviation for Coal-Fired Power Plants
GUI Yishu,SHEN Congqi,CHEN Huanle,CHENG Jiyun,WANG Nianlong,TANG Longsheng,LIU Gang,CHEN Yuanliang.Research and Optimization on Primary Frequency Regulation Characteristics with Large Frequency Deviation for Coal-Fired Power Plants[J].Electric Power,2017,50(4):106-112.
Authors:GUI Yishu  SHEN Congqi  CHEN Huanle  CHENG Jiyun  WANG Nianlong  TANG Longsheng  LIU Gang  CHEN Yuanliang
Affiliation:1. Shanghai MingHua Electric Power Technology & Engineering Co. LTD., Shanghai 200437, China;2. Fengtai Power Plant of Huaizhe Coal & Power Co. LTD., Huainan 232200, China;3. Pingwei Electric Power Co. LTD., Huainan 232000, China;4. Shanghai Wujing No.2 Power Generation Co. LTD., Shanghai 200241, China
Abstract:Through the analysis on two DC power transmission line faults, it is discovered that the characteristics of the dynamic response of coal-fired power plants to primary frequency regulation are generally poor, and the dynamic characteristics of large frequency deviation are completely different from those of small or medium frequency deviation of the power grid. Based on the identification of large frequency deviation model, the primary frequency regulation strategy is optimized, and the experiments of large frequency deviation are conducted with the results being analyzed to estimate the risks of the loading conditions and evaluate the performance of the primary frequency regulation with large frequency deviation for coal-fired power plants so as to effectively improve the primary frequency regulation performance on the premise of ensuring the unit safe operation, which benefits both the power grid and the generating units.
Keywords:coal-fired power generation unit  large frequency deviation  primary frequency regulation  model identification  control strategy  optimization  risk evaluation  
本文献已被 CNKI 等数据库收录!
点击此处可从《中国电力》浏览原始摘要信息
点击此处可从《中国电力》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号