1000MW超超临界锅炉水冷壁T23管泄漏分析及处理
引用本文:王昌文,何鹏.1000MW超超临界锅炉水冷壁T23管泄漏分析及处理[J].上海电力学院学报,2014,30(4):339-345.
作者姓名:王昌文  何鹏
作者单位:皖能铜陵发电有限公司;安徽电气工程职业技术学院;
摘    要:某1 000 MW超超临界燃煤发电塔式锅炉水冷壁在投运一段时间后,出现了管道泄漏和裂纹的现象.在充分考虑T23钢的材料性能的基础上,对该问题的原因进行了分析,并提出了应对措施,及时消除了水冷壁泄漏的隐患,为类似问题的解决提供了参考.

关 键 词:超超临界  锅炉  水冷壁管  泄漏
收稿时间:6/9/2014 12:00:00 AM

Analysis of the Leakage of T23 Water Wall Tube of 1 000 MW Ultra Supercritical Boiler
WANG Changwen and HE Peng.Analysis of the Leakage of T23 Water Wall Tube of 1 000 MW Ultra Supercritical Boiler[J].Journal of Shanghai University of Electric Power,2014,30(4):339-345.
Authors:WANG Changwen and HE Peng
Affiliation:Wanneng Tongling Generation Co. Ltd., Tongling 244012, China and Anhui Electrical Engineering Vocational Technical Institute, Hefei 230051, China
Abstract:There appeared pipeline leakage and crack in the tower boiler water wall of 1000 MW ultra-supercritical coal-fired power generating units after the units had been put into operation for a period of time. The problems are analyzed and the countermeasures put forward could eliminate the water wall leakage hidden troubles in a timely manner on the basis of fully considering the peculiarity of T23 steel tubes performance. Some solutions to similar problems are offered for references.
Keywords:ultra supercritical  boiler  water wall tube  leakage