首页 | 本学科首页   官方微博 | 高级检索  
     


Uncertainties in personal dosimetry for external radiation: a Monte Carlo approach
Authors:van Dijk J W E
Affiliation:NRG Radiation and Environment, P.O. Box 3094, 6800 ES Arnhem, The Netherlands. j.vandijk@nrg-nl.com
Abstract:This paper explores the possibilities of numerical methods for uncertainty analysis of personal dosimetry systems. Using a numerical method based on Monte Carlo sampling the probability density function (PDF) of the dose measured using a personal dosemeter can be calculated using type-test measurements. From this PDF the combined standard uncertainty in the measurements with the dosemeter and the confidence interval can be calculated. The method calculates the output PDF directly from the PDFs of the inputs of the system such as the spectral distribution of the radiation and distributions of detector parameters like sensitivity and zero signal. The method can be used not only in its own right but also for validating other methods because it is not limited by restrictions that apply to using the Law of Propagation of Uncertainty and the Central Limit Theorem. The use of the method is demonstrated using the type-test data of the NRG-TLD.
Keywords:
本文献已被 PubMed Oxford 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号