首页 | 本学科首页   官方微博 | 高级检索  
     

一种转子流量计流量公式的严谨推导方法
引用本文:魏书田.一种转子流量计流量公式的严谨推导方法[J].内蒙古石油化工,2007,33(6):68-69.
作者姓名:魏书田
作者单位:山东工商学院,信电学院,烟台,264003
摘    要:化工原理教材中,转子流量计流量公式是仿照孔板流量计的推导方法给出的。这种方法认为动能变化是产生压力降的原因,与转子计事实不符。本文运用柏努利方程给出了严格的推导,并给出了实测的结果。

关 键 词:转子流量计  流量测量  化工原理
修稿时间:2007-01-10

A Rigorous Approach to the Deduction of the Flow Rate Equation for Votor Flowmeter
WEI Shu-tian.A Rigorous Approach to the Deduction of the Flow Rate Equation for Votor Flowmeter[J].Inner Mongulia Petrochemical Industry,2007,33(6):68-69.
Authors:WEI Shu-tian
Affiliation:School of Information and Electronic Engineering,Shandong Institute of Business and Technology,Yantai 264003
Abstract:In scientific literature,the flow rate equation for votor flowmeter is deducted with the reference to the flow rate equation for borehole flowmeter.It is believed,with this approach,that the kinetic energy change is the cause of the decrease in pressure,which is contradictive to the rotor meter.This paper tries to deduct rigorously the equation for the flow rate by using the Bernoulli equation,and to provide the expression of flow rate coefficient.Eventually the test result of the flow rate coefficient is offered.
Keywords:votor flowmeter  measurement of flow fate  chemical engineering principle