The potential transformer bridge with current comparator formeasuring the voltage dependence of compressed-gas capacitors
Authors:Castelli  F
Affiliation:Dept. of Elettrotecnica, Polytech. of Milan;
Abstract:In this paper, an alternative method for measuring the voltage dependent capacitance variation (VDCV) of compressed-gas capacitors is described. In the proposed method, the VDCV of the capacitor under test is measured by comparing it with a capacitor standard supplied with the secondary (low) voltage of a potential transformer. This transformer has its primary parallel connected with the capacitor under test. The paper presents and criticizes the test results obtained in which an uncertainty of at least 0.5 ppm is achieved
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏