首页 | 本学科首页   官方微博 | 高级检索  
     


Analysis of non-cleaned QuEChERS extracts for the determination of pesticide residues in fruit,vegetables and cereals by gas chromatography-tandem mass spectrometry
Authors:Hans Ragnar Norli  Agnethe L Christiansen  Kari Stuveseth
Affiliation:1. Norwegian Institute of Bioeconomy Research, Plant Health and Biotechnology Division, Pesticide Chemistry Section, ?s, Norwayhansragnar.norli@nibio.no;3. Norwegian Institute of Bioeconomy Research, Plant Health and Biotechnology Division, Pesticide Chemistry Section, ?s, Norway
Abstract:This paper investigated the possibility of leaving out the traditional clean-up step in the QuEChERS procedure and analysing non-cleaned extracts from fruit, vegetables and cereals with a combination of gas chromatography-tandem mass spectrometry (GC-MS/MS), back-flush technology and large-volume injection. By using calibration standards in cucumber matrix, recovery and precision were calculated in lettuce, orange and wheat for 109 pesticides at 0.01 and 0.1 mg kg?1 in two sets of samples: one with and one without clean-up. For both spiking levels, 80–82% of the pesticides in the non-cleaned extracts and 80–84% of the pesticides in the cleaned extracts were within the acceptable recovery range of 70–120%. Precision data for both levels showed that 95% of the pesticides in the non-cleaned extracts and 93–95% of the pesticides in the cleaned extracts had RSDs below 20%. Recovery and precision data were determined using a two tailed t-test (p = 0.05). By using calibration standards in the respective matrix, we studied if the non-cleaned calibration standards gave an extra matrix effect compared with the cleaned standards by using the slope from calibration graphs and plotting the calculated extra matrix effect minus 100 for each compound. The results showed that for 79% of the pesticides, the extra matrix effect minus 100 was within the acceptable range of ?20% to 20%. Five European Union proficiency tests on rye, mandarin, rice, pear and barley, respectively, from 2010 to 2012 were reanalysed omitting the clean-up step and showed satisfactory results. At least 70 injections of non-cleaned extracts were made without detecting any increased need for maintenance during the experimental period. Analysing non-cleaned QuEChERS extracts of lettuce, orange and wheat are possible under the conditions described in this paper because recovery, precision and specificity showed satisfactory results compared with samples subjected to traditional dispersive clean-up.
Keywords:Pesticide residue  fruit  vegetables  cereals  GC-MS/MS  back-flush  large volume injection (LVI)  QuEChERS  matrix effects
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号