首页 | 本学科首页   官方微博 | 高级检索  
     

伺服系统开环传递函数增益的精确测量
引用本文:陈洪立,翟林培,陈占军. 伺服系统开环传递函数增益的精确测量[J]. 电子测量技术, 2008, 31(9)
作者姓名:陈洪立  翟林培  陈占军
作者单位:1. 中国科学院长春光学精密机械与物理研究所,长春,130033;中国科学院研究生院,北京,100049
2. 中国科学院长春光学精密机械与物理研究所,长春,130033
摘    要:用传统频率法测量了一套机电伺服系统的开环传递函数,发现测量的传递函数增益的相对误差是40%。分析了该方法测定增益时产生误差的原因,并提出了一种测量增益的新方法,且进行了实验。实验结果表明新方法测量的增益相对误差是9%,测量准确度比传统频率法提高了4.4倍。

关 键 词:伺服系统  传递函数  增益  精确测量

Accurate measurement to D.C.gain of open-looped transfer function for servo system
Chen Hongli,Zhai Linpei,Chen Zhanjun. Accurate measurement to D.C.gain of open-looped transfer function for servo system[J]. Electronic Measurement Technology, 2008, 31(9)
Authors:Chen Hongli  Zhai Linpei  Chen Zhanjun
Abstract:Transfer function(TF) of a servo system was measured by frequency response method.The relative error of the d.c.gain of the TF was 40%.A new method to measure d.c.gain was presented.Experimental result indicates that the relative error of d.c.gain measured by the new method was 9%.Measure veracity was improved by 4.4 times.
Keywords:servo system  transfer function  d.c.gain  exact measuring