横管初冷器阻力增大原因分析与改进
引用本文:李超,卢艳军,武辉斌. 横管初冷器阻力增大原因分析与改进[J]. 燃料与化工, 2013, 0(6): 53-54,56
作者姓名:李超  卢艳军  武辉斌
作者单位:太原煤炭气化集团焦化厂,太原030024
摘    要:介绍了横管初冷器在运行中存在的问题并进行改进,解决了初冷器阻力大、冷却效果差、蒸汽吹扫频繁的问题,实现了横管初冷器的连续、稳定运行。

关 键 词:横管初冷器  阻力  改进

Cause analysis and improvement of resistance increasing of cross-pipe primary cooler
Li Chao Lu Yanjun Wu Huibin. Cause analysis and improvement of resistance increasing of cross-pipe primary cooler[J]. Fuel & Chemical Processes, 2013, 0(6): 53-54,56
Authors:Li Chao Lu Yanjun Wu Huibin
Affiliation:Li Chao Lu Yanjun Wu Huibin (Coking Plant of Taiyuan Coal Gasification Group,Taiyuan 030024,China)
Abstract:This paper analyzes the problems of cross-pipe primary cooler found during operation, and puts forward methods for improvement. The problems of high resistance, poor cooling effect and frequent purge are solved, so the cross-pipe primary cooler can run in stable and continuous condition.
Keywords:Cross-pipe primary cooler  Resistance  Improvement