首页 | 本学科首页   官方微博 | 高级检索  
     


Purification of Phenolic Wastewater Using Aerobic Bio-oxidation Combined with Activated Carbon Treatment and Ozonation
Authors:Oliver Järvik  Inna Kamenev  Andres Viiroja  Juha Kallas
Affiliation:1. Department of Chemical Engineering , Tallinn University of Technology , Tallinn, 19086, Estonia;2. Department of Chemical Technology , Lappeenranta University of Technology , Fin-53851, Lappeenranta, Finland
Abstract:The combined process – aerobic bio-oxidation with activated carbon addition and ozonation was studied (ABO/AC/O3). The performance of the process was compared with conventional aerobic bio-oxidation (ABO). The studies were carried out in two continuous and periodic reactors to evaluate the purification efficiencies (in terms of COD, BOD and resorcinols removal), excess sludge generation and stability of the bioreactors against shock loadings. The parameters in continuous combined process were as follows: organics loading was 620 mgCOD/(day·L), activated carbon concentration 1g/L and ozone dose 2.45 mgO3/L (mg ozone per liter of treated water). In periodic reactors the combined process was studied at lower activated carbon concentration and ozone dose (0.3 g/L and 0.57 mg/L respectively).

The results indicated that compared with conventional ABO, the co-effect of AC addition and short-termed (less than 1 week) or intermittent ozonation improved the removal of COD and BOD, while the longer period of ozonation resulted in reduction of excess sludge concentration in the bioreactor. The impact of AC and ozone on the ABO in the combined process did not concern only increased biomass activity, but AC and ozone improved also settleability of activated sludge and enhanced stability of the bioreactor to shock loadings.

Keywords:Ozone  Activated carbon  Aerobic bio-oxidation  Combined process  resorcinols  Excess sludge  Phenolic wastewater  Oil shale industry
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号