摘    要:衢州电力局调度交换网采用2台H20-20交换机作为交换节点,调度台左右手柄分别从2台交换机接出,这种组网方式增加了系统的可靠性,但也增加了运行维护的复杂度。文章对日常运维中出现的典型故障进行分析,提出了相应的解决方案,为相关人员提供了借鉴与参考。

关 键 词:调度交换网  调度台  故障  分析
文章编号:1005-7641(2008)02-0064-04
收稿时间:2007-08-10
修稿时间:2007-09-23

Faults analysis in dispatching exchange network
LIU Wei-hong.Faults analysis in dispatching exchange network[J].Telecommunications for Electric Power System,2008,29(2):64-67.
Authors:LIU Wei-hong
Abstract:The dispatching exchange network in Quzhou Electric Power Bureau uses two Harris 20-20 exchanges as switching nodes. The left and right handsets of dispatching console access from two exchanges respectively. Although this networking method increases the system reliability, it leads to a complicated maintenance. This paper analyzes several typical faults frequently occurring in daily operation and maintenance, and provides some corresponding solutions as a reference for related personnel.