LPG灶具改用天然气的实验研究
引用本文:李帆,张成毅,管延文,安翠林,刘毅.LPG灶具改用天然气的实验研究[J].煤气与热力,2005,25(1):29-30.
作者姓名:李帆  张成毅  管延文  安翠林  刘毅
作者单位:华中科技大学环境科学与工程学院,湖北,武汉,430074;武汉市燃气用具检测站,湖北,武汉,430010
摘    要:对3台LPG灶具进行天然气转换改造,分析了手工扩孔对灶具适应性的影响。手工扩孔易造成热负荷及CO体积分数超标等问题,灶具改造应由专业厂家进行。

关 键 词:LPG灶具  天然气转换  燃具适应性  燃具改造
文章编号:1000-4416(2005)01-0029-02

Experimental Study on LPG Ranges Converted to Natural Gas
LI Fan,ZHANG Cheng-yi,GUAN Yan-wen,AN Cui-lin,LIU Yi.Experimental Study on LPG Ranges Converted to Natural Gas[J].Gas & Heat,2005,25(1):29-30.
Authors:LI Fan  ZHANG Cheng-yi  GUAN Yan-wen  AN Cui-lin  LIU Yi
Affiliation:LI Fan~1,ZHANG Cheng-yi~1,GUAN Yan-wen~1,AN Cui-lin~2,LIU Yi~2
Abstract:After the reform of 3 LPG ranges by natural gas conversion, the influence of manual reaming on the adaptability of gas range is analyzed. The manual reaming is easy to cause problems, such as over norm of heat load and CO volume fraction. The reform of gas range should be conducted by specialized manufacturers.
Keywords:LPG  range  natural gas conversion  adaptability of gas appliance  reform of  gas  appliance  