首页 | 本学科首页   官方微博 | 高级检索  
     

基于动态透平效率的有机朗肯循环性能分析及优化
引用本文:李鹏,韩中合,贾晓强,梅中恺,韩旭. 基于动态透平效率的有机朗肯循环性能分析及优化[J]. 太阳能学报, 2021, 0(3): 406-413
作者姓名:李鹏  韩中合  贾晓强  梅中恺  韩旭
作者单位:华北电力大学电站设备状态监测与控制教育部重点实验室
基金项目:国家自然科学基金(51306059);中央高校基本科研业务费专项资金(2017XS120)。
摘    要:常规有机朗肯循环(ORC)中透平效率多假设为定值,而实际上透平效率因工质种类和运行参数的不同而有较大差异.因此,采用向心透平效率计算模型,将动态透平效率与ORC系统耦合,分析透平效率随蒸发温度与冷凝温度的变化规律,比较固定透平效率与动态透平效率ORC系统热效率的差异.综合考虑热力性与经济性,采用多目标优化算法,对固定透...

关 键 词:有机朗肯循环  动态透平效率  多目标优化  综合性能

PERFORMANCE ANALYSIS AND OPTIMIZATION OF ORGANIC RANKINE CYCLE BASED ON DYNAMIC TURBINE EFFICIENCY
Li Peng,Han Zhonghe,Jia Xiaoqiang,Mei Zhongkai,Han Xu. PERFORMANCE ANALYSIS AND OPTIMIZATION OF ORGANIC RANKINE CYCLE BASED ON DYNAMIC TURBINE EFFICIENCY[J]. Acta Energiae Solaris Sinica, 2021, 0(3): 406-413
Authors:Li Peng  Han Zhonghe  Jia Xiaoqiang  Mei Zhongkai  Han Xu
Affiliation:(Key Lab of Condition Monitoring and Control for Power Plant Equipment(North China Electric Power University),Ministry of Education,Baoding 071003,China)
Abstract:Turbine efficiency is generally assumed to be a constant value in the conventional organic Rankine cycle(ORC). A turbine efficiency varies with the type of working fluids and the operating parameters. Therefore,a calculation model of the turbine efficiency is presented and the dynamic turbine efficiency is coupled with ORC system. The variation of the turbine efficiency with evaporation temperature and condensation temperature were analyzed,and thermal efficiency of ORC system with constant turbine efficiency and dynamic turbine efficiency were compared. Considering thermodynamic and economic performances,multi-objective algorithm was adopted to select the optimal working fluid and determine the operating parameters for constant turbine efficiency ORC system and dynamic turbine efficiency ORC system,and the optimal results were compared and analyzed. The results show that the turbine efficiency increases with the decrement of evaporation temperature or the increment of condensation temperature. Turbine efficiency is different for different working fluids and operating parameters,the maximum difference value is 0.148. There is significant difference of thermal efficiency between constant turbine efficiency ORC and dynamic turbine efficiency ORC,which is more obvious in high evaporation temperature range. For constant turbine efficiency ORC system,R245 ca and R236 ea are the optimal working fluids,while for dynamic turbine efficiency ORC system,R114 is the optimal working fluid. The optimal evaporation and condensation temperature changed a lot after the introduction of dynamic turbine efficiency.
Keywords:organic Rankine cycle  dynamic turbine efficiency  multi-objective optimization  comprehensive performance
本文献已被 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏