电感耦合等离子体原子发射光谱法测定锆铪合金中磷铁铪
引用本文:杜米芳.电感耦合等离子体原子发射光谱法测定锆铪合金中磷铁铪[J].冶金分析,1982,40(2):72-75.
作者姓名:杜米芳
作者单位:中国船舶重工集团公司第七二五研究所,河南洛阳 471023
摘    要:锆铪合金性能优异、应用广泛,其化学成分须准确测定。试验采用10mL盐酸-2mL氢氟酸-1mL硝酸消解样品,选择P 178.221nm、Fe 239.562nm、Hf 277.336nm为分析线并采用两点校正法扣除背景,建立了电感耦合等离子体原子发射光谱法(ICP-AES)测定锆铪合金中磷、铁、铪的分析方法。各元素校准曲线线性良好,相关系数均不小于0.999;方法测定范围为:0.002%~0.036%磷,0.01%~0.36%铁,1.00%~5.00%铪。方法中各元素检出限为0.000032%~0.0019%(质量分数)。按照实验方法测定1个锆铪合金样品中磷、铁、铪,测定结果的相对标准偏差(RSD,n=10)小于3%;回收率为94%~107%。

关 键 词:电感耦合等离子体原子发射光谱法  锆铪合金        
收稿时间:2019-07-04

Determination of phosphorus,iron and hafnium in zirconium-hafniumalloy by inductively coupled plasma atomic emission spectrometry
DU Mi-fang.Determination of phosphorus,iron and hafnium in zirconium-hafniumalloy by inductively coupled plasma atomic emission spectrometry[J].Metallurgical Analysis,1982,40(2):72-75.
Authors:DU Mi-fang
Affiliation:Luo Yang Ship Materials Institute, Luoyang 471023, China
Abstract:Zirconium-hafnium alloy has excellent properties and it has been widely used. The chemical composition of zirconium-hafnium alloy should be determined accurately. The sample was dissolved with 10mL of hydrochloric acid-2mL of hydrofluoric acid-1mL of nitric acid. P 178.221nm, Fe 239.562nm and Hf 277.336nm were selected as the analytical line. The background was deducted by two-point correction method. The determination method of phosphorus, iron and hafnium in zirconium-hafnium alloy by inductively coupled plasma atomic emission spectrometry (ICP-AES) was established. The calibration curves of elements had good linearity and the correlation coefficients were all higher than 0.999. The determination range of the method was 0.002%-0.036% for phosphorus, 0.01%-0.36% for iron and 1.00%-5.00% for hafnium, respectively. The limit of detection of elements were in range of 0.000032%-0.0019% (mass fraction). The contents of phosphorus, iron and hafnium in one zirconium-hafnium alloy sample were determined according to the experimental method. The relative standard deviations (RSD, n=10) of determination results were less than 3%, and the recoveries were between 94% and 107%.
Keywords:inductively coupled plasma atomic emission spectrometry (ICP-AES)  zirconium-hafnium alloy  phosphorus  iron  hafnium  