首页 | 本学科首页   官方微博 | 高级检索  
     

钢管压扁断裂原因分析
引用本文:王宏霞,吕学星.钢管压扁断裂原因分析[J].理化检验(物理分册),2006,42(6):309-310,314.
作者姓名:王宏霞  吕学星
作者单位:山东泰山钢铁集团有限公司研究所,莱芜,271100
摘    要:用带钢制成的钢管在压扁试验中出现断裂。采用扫描电镜、能谱和金相分析等方法,对断裂试样进行了夹杂物、晶粒度、显微组织、断口及氧含量的检验和分析。结果表明,钢中夹杂物多和氧含量偏高是导致压扁断裂的主要原因。

关 键 词:钢带  氧含量  夹杂物  压扁断裂
文章编号:1001-4012(2006)06-0309-02
收稿时间:2005-05-08
修稿时间:2005-05-08

CAUSE ANALYSIS FOR BENDING-RUPTURE FAILURE OF WELDED TUBE
WANG Hong-xia,LV Xue-xing.CAUSE ANALYSIS FOR BENDING-RUPTURE FAILURE OF WELDED TUBE[J].Physical Testing and Chemical Analysis Part A:Physical Testing,2006,42(6):309-310,314.
Authors:WANG Hong-xia  LV Xue-xing
Affiliation:Research Institute of ShanDong TaiShan Iron and Steel Group Co. Ltd. , Laiwu 271100, China
Abstract:The examination and analysis included microstructure, inclusions, graininess, fracture, oxygen content of unqualified cold bending strip were done by means of XL30SEM, EDA and metallograph analysis and so on. The result shows that the unqualified cause of cold bending strip steel is high oxygen content, high inclusion content, etc.
Keywords:Strip steel  Oxygen content  Inclusion  Bending-rupture