首页 | 本学科首页   官方微博 | 高级检索  
     

用热电偶测量灭弧室内SF_6热气体温度探究
引用本文:贾志鸿 郭文元. 用热电偶测量灭弧室内SF_6热气体温度探究[J]. 高压电器, 1998, 34(1): 19-21,33
作者姓名:贾志鸿 郭文元
作者单位:西安交通大学
摘    要:应用控制论原理,求得热电偶传递函数后,利用实测得的热电偶输出电压曲线,分段拟合及拉氏反变换处理,可推算出被测气体的实际温度。此外,依据传热学中相似准则介绍了处在SF_6强迫对流中的热电偶时间常数的计算方法。

关 键 词:热电偶  自能式灭弧室  六氟化硫  温度

Study in Measuring the Hot Flow Gas Temperature in Arc-extiguishing Chamber of SF Puffer Circuit Breaker by Using Thermocouple
Jia Zhihong,Lie Ying,Guo wenyuan. Study in Measuring the Hot Flow Gas Temperature in Arc-extiguishing Chamber of SF Puffer Circuit Breaker by Using Thermocouple[J]. High Voltage Apparatus, 1998, 34(1): 19-21,33
Authors:Jia Zhihong  Lie Ying  Guo wenyuan
Abstract:Based on control principles, the output voltage curve can be sec-tionalized fitting and inverse Laplace transformed, so we can calculate the real temperature of hot flow gas after getting the transfer function of thermocouple. According to the similar rule in heat transfer theory,we introduce the calculating method of time content of thermocouple under the forced flow condition.
Keywords:thermocouple  self-energy interrupter  SF6  temperature.