首页 | 本学科首页   官方微博 | 高级检索  
     


Analysis on thermophoretic deposit of fine particle on water wall of 10 MW high temperature gas-cooled reactor
Authors:ZHOU Tao  YANG Rui-chang  JIA Dou-nan
Affiliation:1. Department of Thernal Engineering,Tsinghua University,Beijing,100084
2. Department of Nuclear Energy,Xi'an Jiaotong University,Xi'an,710049
Abstract:The water wall is an important part of the passive natural circulation residual heat removal system in a high temperature gas-cooled reactor. The maximum temperatures of the pressure shell and the water wall are calculated using annular vertical closed cavity model. Fine particles can deposit on the water wall due to the thermophore sis effect. This deposit can affect heat transfer. The thermophoretic deposit efficiency is calculated by using Batch and Shen's formula fitted for both laminar flow and turbulent flow. The calculated results indicate that natural convection is turbulent in the closed cavity. The transient thermophoretic deposit efficiency rises with the increase of the pressure shell's temperature. Its maximum value is 14%.
Keywords:High temperature gas-cooled reactor   Water wall   Fine particles   Thermophoretic deposit
本文献已被 CNKI 维普 万方数据 等数据库收录!