首页 | 本学科首页   官方微博 | 高级检索  
     

调节级压力取样管泄漏后的应急处理研究
引用本文:吕松.调节级压力取样管泄漏后的应急处理研究[J].贵州电力技术,2012(8):42-44.
作者姓名:吕松
作者单位:贵州大方发电有限公司,贵州大方551600
摘    要:某国产引进型300MW汽轮机组汽轮机本体大修后因调节级压力信号管焊口断裂,导致运行时调节级压力信号失灵,DCS负荷调节全部中断,为此提出了若干解决方案,避免了再次揭缸大修。

关 键 词:汽轮机  安全运行  调节级压力  运行方式

Study on emergency treatment after the control stage pressure sampling tube leak
Lv Song.Study on emergency treatment after the control stage pressure sampling tube leak[J].Guizhou Electric Power Technology,2012(8):42-44.
Authors:Lv Song
Affiliation:Lv Song ( Dafang Electric Power Plant, Dafang 551600 Guizhou, China)
Abstract:Due to the fracture of control stage pressure signal pipe weld at its overhaul, the control stage pressure signal of a domestic introduction of 300MW steam turbine was led to failure at run -time, and DCS load regulations were all interrupted. For this situation, this paper proposed several solutions to avoid reexposing the cylinder overhaul.
Keywords:steam turbine  safe operation  control stage pressure  operation mode