摘    要:烧结脱硫烟气流量计的量程是基于一定温度、压力条件下的标况量程,对于监控的工况流量,需要根据实际工况重新计算差压和对应的量程,详细介绍了量程修正计算的方法和过程。

关 键 词:脱硫烟气  流量计  标况  工况  量程

Amendment Method for the Flowmeter Span of the Sintering Waste Gas Desulfuration
Han Jun.Amendment Method for the Flowmeter Span of the Sintering Waste Gas Desulfuration[J].Metallurgical Equipment,2011(Z1):14-15.
Authors:Han Jun
Affiliation:Han Jun(Iron Making Plant of Baoshan Iron and Steel Joint Stock Co.,Ltd.,Shanghai 201900)
Abstract:The flowmeter span of the sintering waste gas desulfuration is the standard conditions span based on the given temperature and pressure.For the working conditions flow,it is necessary to calculate the differential pressure and span based on the real conditions.The arithmetic and process for Conversion span have been discussed detailedly.
Keywords:Waste gas desulfuration Flowmeter Standard condition Working condition Span  