首页 | 本学科首页   官方微博 | 高级检索  
     


Thermal effects in the Input Optics of the Enhanced Laser Interferometer Gravitational-Wave Observatory interferometers
Authors:Dooley Katherine L  Arain Muzammil A  Feldbaum David  Frolov Valery V  Heintze Matthew  Hoak Daniel  Khazanov Efim A  Lucianetti Antonio  Martin Rodica M  Mueller Guido  Palashov Oleg  Quetschke Volker  Reitze David H  Savage R L  Tanner D B  Williams Luke F  Wu Wan
Affiliation:University of Florida, Gainesville, Florida 32611, USA. kate.dooley@aei.mpg.de
Abstract:We present the design and performance of the LIGO Input Optics subsystem as implemented for the sixth science run of the LIGO interferometers. The Initial LIGO Input Optics experienced thermal side effects when operating with 7 W input power. We designed, built, and implemented improved versions of the Input Optics for Enhanced LIGO, an incremental upgrade to the Initial LIGO interferometers, designed to run with 30 W input power. At four times the power of Initial LIGO, the Enhanced LIGO Input Optics demonstrated improved performance including better optical isolation, less thermal drift, minimal thermal lensing, and higher optical efficiency. The success of the Input Optics design fosters confidence for its ability to perform well in Advanced LIGO.